\subsection{IPU Data Format}
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+Each word sent by an OEP can be of three types as shown in table \ref{MDCDataFormat}:
+\begin{itemize}
+ \item The standard, compressed data format with two hits in one data word
+ \item The long, debug format, with one word per hit.
+ \item Status words which can be of several types, see table \ref{MDCDataFormatStatusWords}
+\end{itemize}
+
+
\begin{table}[hb]
\begin{center}
\begin{tabular}{|c|c|c|c|}
31 & 0 & 1 & 0 \\
30 & 0 & 0 & 1 \\
29 & 0 & 0 & 0 \\
-28 .. 25 & TDC number & TDC number & status data \\
-24 .. 22 & TDC channel & TDC channel & status data \\
-21 .. 11 & Bit 21: Hit number, rest 0 & ADC data - Hit 1 & status data \\
-10 .. 0 & ADC data & ADC data - Hit 0 & status data \\
+28 -- 25 & TDC number & TDC number & word code \\
+24 -- 22 & TDC channel & TDC channel & 24: code, 23..0: data \\
+21 -- 11 & Bit 21: Hit number, rest 0 & ADC data - Hit 1 & data \\
+10 -- 0 & ADC data & ADC data - Hit 0 & data \\
\hline
\end{tabular}
\caption{MDC data format}
\end{center}
\end{table}
+\begin{table}[hb]
+\begin{center}
+\begin{tabularx}{\textwidth}{|c|c|X|c|}
+\hline
+\textbf{Name} & \textbf{Code} & \textbf{Content} & \textbf{Note}\\
+\hline
+\hline
+Basic Information & 0x00 & Bit 15 -- 0: Internal trigger number, Bit 16: Short MBO, Bit 17: Long MBO, Bit 18: CMS active & \\
+Token Missing & 0x01 & Bit 23 -- 0: Number of missing token & 1\\
+Phys. Triggers & 0x02 & Bit 23 -- 0: Number of received triggers & 1 \\
+Calib. Triggers & 0x03 & Bit 23 -- 0: Number of received calibration triggers & 1 \\
+Discarded Hit 1 & 0x04 & Bit 23 -- 0: Number of discarded hit~1 words from TDC due to threshold setting & 1 \\
+Discarded Hit 0 & 0x05 & Bit 23 -- 0: Number of discarded hit~0 words from TDC due to threshold setting & 1 \\
+Discarded Words & 0x06 & Bit 23 -- 0: Number of discarded words due to limit of words per event & 1 \\
+Truncated Events& 0x07 & Bit 23 -- 0: Number of truncated events due to limit of words per event & 1 \\
+Single Hit 1 & 0x08 & Bit 23 -- 0: Number of single, double or triple hit 1 & 1 \\
+Single Hit 0 & 0x09 & Bit 23 -- 0: Number of single, double or triple hit 0 & 1 \\
+Retransmit Req. & 0x0A & Bit 11 -- 0: Number of retransmit requests sent, Bit 23 -- 12: Number of retransmit requests received & 1\\
+Dummy Word & 0x1E & Dummy data word. Sent in every event when selected by CCR2 Bit 22 (see table \ref{MDCCommonCtrlReg2}). Bit 23 -- 16: Lower 8 bit of trigger number. Bit 11 -- 0: Word counter & \\
+Debug Word & 0x1F & Debug word. Sent in every event when selected by CCR2 Bit 30 (see table \ref{MDCCommonCtrlReg2}). Bit 15 -- 0: Trigger number & \\
+\hline
+\end{tabularx}
+\caption{MDC status words. Note 1: is reset when CCR0 Bit 5 is set. In the 0xE-event, the relative counter value since the last 0xE-event is shown. The status words 0x00 to 0x1D are also available in the address range 0x9100 to 0x911D. Here, the absolute counter value is read.}
+\label{MDCDataFormatStatusWords}
+\end{center}
+\end{table}
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
\subsection{Memory Map}
\hline
8000 - 803F & ADC & Voltage monitoring ADC. see table \ref{MDCOEPADCMemoryMap} \\
9000 - 90FF & Status & Status of the various state machines and control signals \\
+9100 - 91FF & Statistics & Various statistics regarding data and MBO status. For details see table \ref{MDCDataFormatStatusWords}. N.B. in these registers the cummulative values are shown. \\
A000 - A0FF & Config. Mem. & Configuration memory for thresholds and TDC settings \\
D000 & SPI Status Reg. & see section SPI Flash \\
D001 & SPI Control Reg. & see section SPI Flash \\
\item[Bit 2] CMS active
\end{description}
-
\item[0x9001: \filename{Trigger\_Handler} status register] ~
\begin{description}
- \item[Bit 3..0] State machine: 0: Idle, 1: Begrun, 2: timing trigger, 3: calibration trigger, 4: do readout
+ \item[Bit 3..0] State machine: 0: Idle, 1: Begrun, 2: timing trigger, 3: calibration trigger, 4: do readout, 5: wait for data, 6: release lvl1, 7: do reinit, 8: do reinit 2
\end{description}
-
\item[0x9002: \filename{Data\_Handler} status register]~
\begin{description}
- \item[Bit 3 -- 0] State machine status
+ \item[Bit 3 -- 0] State machine status \\ 0: idle, 1: send data, 2: send long data, 3: send dummy, 4: finish, 5: write debug word, 6: prepare status information, 7: send status information
\item[Bit 4] Start Readout
\item[Bit 5] Finished Readout
\item[Bit 6] Data Write Enable
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
-\subsection{Board Positions}
+\subsection{Hardware}
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
\subsubsection{MDC OEP Positions}
\end{figure}
\subsubsection{MDC AddOn Connections}
-Due to very different cable length, there is no clear rule where which OEP is connected. See section \ref{mdcaddonconnections} for details.
\ No newline at end of file
+Due to very different cable length, there is no clear rule where which OEP is connected. See section \ref{mdcaddonconnections} for details.
+
+%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+\subsubsection{FanPW}
+%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
+One voltage regulator block on the FanPW is shown in figure \ref{fanpw}. The position of each of the five potentiometers is shown.
+
+The suggested voltage settings are:
+\begin{itemize}
+ \item 6V: Set to 5.85V, resp. 6.2V due to heavy noise on power cable
+ \item 3.8V: Set to 3.8V, resp. 4.1V
+ \item 1.8V: Set to 1.8V, resp. 2.1V
+ \item +3V: Set to approx. 3.1V (should be 3.0V $\pm$ 0.05V on the OEP)
+ \item -3V: Set to approx. -3.1V (should be -3.0V $\pm$ 0.05V on the OEP)
+\end{itemize}
+
+
+\begin{figure}
+ \centering
+ \includegraphics[width=.7\textwidth]{fanpw_poti.png}
+\caption{FanPW potentiometer positions.}
+\label{fanpw}
+\end{figure}