<field name="MonitorCounter" start="0" bits="24" format="unsigned" noflag="true" />
</register>
</group>
-
+
+ <group name="Trigger" purpose="config" address="0000" size="32" mode="rw" continuous="true">
+ <description>Registers of the trigger generation logic</description>
+ <group name="TriggerGeneration" purpose="config" address="0000" size="2" repeat="16">
+ <register name="TriggerEnable" address="0000" mode="rw" >
+ <description>Enables individual inputs for trigger generation. If enabled, the input adds to the common or</description>
+ <field name="TriggerEnable" start="0" bits="31" format="bitmask" noflag="true">
+ </field>
+ </register>
+ <register name="TriggerInvert" address="0001" mode="rw" >
+ <description>Inverts individual inputs for trigger generation</description>
+ <field name="TriggerInvert" start="0" bits="31" format="bitmask" noflag="true">
+ </field>
+ </register>
+ </group>
+ <register name="TriggerInput" address="0040" mode="r" >
+ <description>Current status of all inputs</description>
+ <field name="TriggerInput" start="0" bits="31" format="bitmask" />
+ </register>
+ <register name="TriggerOutput" address="0041" mode="r" >
+ <description>Current status of all inputs</description>
+ <field name="TriggerOutput" start="0" bits="31" format="bitmask" />
+ </register>
+
+ </group>
</TrbNetEntity>