added Padiwa Threshold Measurements, mt
authorMichael Traxler <M.Traxler@gsi.de>
Thu, 30 Jan 2014 17:12:26 +0000 (18:12 +0100)
committerMichael Traxler <M.Traxler@gsi.de>
Thu, 30 Jan 2014 17:12:26 +0000 (18:12 +0100)
trb3/WasaFrontend.tex

index 16beafd35682a47925e8748fb21fa915d0a334ca..1c8d5b825d6a82f22c4f8e4306066e2c0f675486 100644 (file)
@@ -85,29 +85,30 @@ This feature is not available in all design versions.
 If register 0x26 does not exist, it is not present.
 
 \subsubsection{Temperature Dependence and Compensation: Measurements}
+
 The uncompensated treshold voltage is affected by a thermal variation , around
--150uV per 1°C. For a threshold of 1V and a temperature rise of 35°C (35°C to
-70°C) an offset of 5,5mV has been measured. The linear proportion of the
+-150uV per 1C. For a threshold of 1V and a temperature rise of 35C (35C to
+70C) an offset of 5,5mV has been measured. The linear proportion of the
 thermal variation can be compensated which results in a voltage rise of only
-500uV for a temperature rise of 35°C.
+500uV for a temperature rise of 35C.
 
 The compensation value of 0x02c0 was determined by measurement.
 
 To set the compensation value use the padiwa.pl script. For example
-„./padiwa.pl 0x303 0 comp  02C0“.
+``./padiwa.pl 0x303 0 comp 02C0''.
 
-\begin{figure}[htp]
+\begin{figure}[pwoc]
   \centering
   \includegraphics[width=0.6\textwidth]{figures/padiwa_thresh_without_compensation.pdf}
   \caption[]{Temperature dependence of the threshold without internal compensation.}
-  \label{fig:calibration}
+  \label{fig:pad_without_calib}
 \end{figure}
 
 \begin{figure}[htp]
   \centering
   \includegraphics[width=0.6\textwidth]{figures/padiwa_thresh_with_compensation.pdf}
   \caption[]{Temperature dependence of the threshold without internal compensation.}
-  \label{fig:calibration}
+  \label{fig:pad_with_calib}
 \end{figure}