\part{Daily News for the Operator}
-\textbf{2022/02/03 - this page will be updated during the beamtime}
+\textbf{2022/02/04 - this page will be updated during the beamtime}
\begin{itemize*}
\item Always keep an eye on the rate plots (``Main Screen 4'' on the web page). If you notice any
asymmetry between sectors / parts of detectors, try to do a reload of thresholds for the detector
\item After any of the ``Reboot Hubs`` and DAQ restart: If Eventbuilders do not work, do
a ''Fix missing IP`` and another DAQ restart.
+ \item There is a ''Trigger`` error every now and then, from a board in RICH (70a7), which also
+causes some ''Evt w/ errors``. This is a known, but no real issue and can be ignored.
\end{itemize*}
\clearpage
If a power cycle of the CTS was done, don't forget to ``Reprogram FPGA'' and
``BLR Reinit FPGA'' before the DAQ restart.
+\subsection*{STS FEE}
+After a powercycle of the STS (Fee or Trb, thresholds need to be loaded manually, using ``Threshold
+STS''.
+
\subsection*{Other Subdetectors}
Check section \ref{powersupplies} to see which power supply to switch.
\item Switch off beam on control panel
\item MDC power supply group off (EPICS)
\item ECAL Padiwa Powercycle \\
- Hodo
+ Hodo Powercycle\\
Start Powercycle \\
STS Fee \\
iTof Powercycle \\