<field name="InputDisable" start="0" bits="16" format="bitmask">
</field>
</register>
+
+ <register name="MonitorOffset" address="0005" mode="rw" >
+ <description>Sets the offset for recording micro spill structure with respect to spill start (in bins)</description>
+ <field name="MonitorOffset" start="0" bits="24" format="unsigned" noflag="true" rate="false" >
+ </field>
+ </register>
+
+ <register name="MonitorTrigger" address="0006" mode="r" >
+ <description>Status of automatic trigger of recodring of micro spill structure</description>
+
+ <field name="BinRecordingTriggered" start="0" bits="1" format="boolean">
+ <description>Recording of bins has been triggered</description>
+ </field>
+ <field name="BinFIFO_Full2" start="1" bits="1" format="boolean">
+ <description>Bin Fifo is full, read-out can take place</description>
+ </field>
+ </register>
+
+
</group>
<group name="SpillMonCounts" address="0000" size="5" purpose="config" mode="r" continuous="true">