\affil[1]{Goethe-Universität Frankfurt}
\maketitle
-The on-going development of the support electronics of the CBM Micro-Vertex-Detector (MVD) was
-focused on two major aspects: First, the integration in a new DAQ system (based on the TRB3 system
+The on-going development of the support electronics of the CBM Micro-Vertex-Detector (MVD) focuses
+on two major aspects: First, the integration in a new DAQ system (based on the TRB3 system
developed by HADES) and, second, the design of an integrated control and monitoring interface for
systems consisting of several sensors.
supply and data lines for a sensor on one common cable.
Special care was taken for the most sensitive supply voltage, a biasing voltage for the pixel
-matrices of the sensors. Here, several generation and distribution schemes are foreseen to
+matrices of the sensors. Several generation and distribution schemes were implemented to
investigate which setup results in the best noise performance. Furthermore, all relevant voltages
and currents can be monitored remotely to further study the behavior of sensors and, subsequently,
to design a matching powering scheme for the final detector setup.