In the case that the power cycle triggered the temperature interlock for RICH power supplies.
The 3.3V supply might be blocked by the temperature interlock - restart DAQ, then try to reset it.
-\subsection*{CTS}
-If a power cycle of the CTS was done, don't forget to ``Reprogram FPGA'' and
-``BLR Reinit FPGA'' before the DAQ restart.
-
-\subsection*{STS FEE}
-After a powercycle of the STS (Fee or Trb, thresholds need to be loaded manually, using ``Threshold
-STS''.
\subsection*{Other Subdetectors}
Check section \ref{powersupplies} to see which power supply to switch.
+
+\subsection{Jörg's helpful tips}
+\subsubsection*{ECAL / RPC}
+\begin{itemize}
+\item After an ECAL powercycle most often a ECAL Padiwa powercycle is needed. You can check this
+looking at the ECAL rate plot seeing weird structures (e.g. 8 green dots in a row) or completely
+missing parts.
+
+\item After the powercycle and DAQ restart often the RPC is still not fully operational. Often you
+need to repeat the powercycle until RPC and ECAL (connected to same LV) are both operational again.
+
+\item After the first DAQ restart you should press the Fix missing IP preemptively as otherwise the
+EB might fail.
+\end{itemize}
+
+\subsubsection*{STS}
+\begin{itemize}
+\item Whenever you do an STS powercycle, you need to do "Thresholds STS" if it did not work (you
+see e.g. blue spots in the STS Hit rate plot) do a "Thresholds STS reset" (this takes a bit longer
+as it is comprised of four different scripts)
+\end{itemize}
+
+\subsubsection*{TOF}
+\begin{itemize}
+\item After the TOF powercycle check if the rates in all sectors are equal - if not a "Thresholds
+TOF" is needed.
+\item If settings thresholds doesn't work in the first try, repeat it a couple more times.
+\end{itemize}
+
+\subsubsection*{iTOF}
+\begin{itemize}
+\item After the iTOF powercycle check if the rates in all sectors are equal - if not a "Thresholds
+iTOF" is needed. If this doesn't help, do a "Powercycle iTOF Padiwa" and try again.
+\end{itemize}
+
+\subsubsection*{Procedure if TRBnet fails}
+If suddenly TRBnet fails (normally indicated by every button on the tactical display blinking red)
+do a powercycle of the common group. Thereafter you need to switch on the RICH LV again after
+waiting about 10 seconds.
+If you powercycled the common group, check all the thresholds and rates as explained in the ECAL,
+RPC and TOF sections.
+
+\subsubsection*{General remark}
+\begin{itemize}
+\item If the EBs do not come up after a (or several) power cycles, try a "Fix missing IP".
+\item Sometimes some MDC boards are missing for a longer time such that the tactical overview
+informs you to take action.
+Very often a DAQ restart is sufficient to get these boards working again.
+If however after some minutes the exact same MDC boards go missing again, you should consider a LV
+power cycle of the respective sectors when you restart the DAQ next time.
+
+\item If boards frequently fail to reboot after a power cycle you might consider switching off the
+beam for the power cycling and subsequent startup procedure. You can do that via the PC in the
+server room.
+
+\end{itemize}
+
\subsection*{Full Powercycle}
A full powercycle should only be done after contact with an expert. Follow the guide for the
``Daily DAQ reboot''.
\item Switch off beam on control panel\\
Switch EB to No File
\item MDC power supply group off (EPICS)\\
- Common Group power supply group power cycle (EPICS)
+ Common Group power supply power cycle (EPICS)
\item RICH power supply group power cycle (EPICS)
\item ECAL Padiwa Powercycle \\
Hodo Powercycle\\
Start Powercycle \\
STS Fee Powercycle\\
- iTof Powercycle \\
+ iTof Padiwa Powercycle \\
Triggerbox Beam Powercycle
BLR Reinit FPGA
\item Start DAQ (x2, because of MDC Hubs)
\item Run Fix Missing IP
-\item MDC power supply group on (EPICS)
+\item MDC power supply group on (EPICS) \\
MDC LV Turn On All Relais
\item Reboot OEP
\item Start DAQ
-\item Thresholds STS Reset\
+\item Thresholds STS Reset\\
Check Eventbuilders getting data / all boards have IPs
\item Switch on beam