--- /dev/null
+\section{Short Manual}
+
+\subsection{What is the starting point?}
+
+Open the DAQ-Control GUI (HadesControl Icon), click on "Hmon". A firefox window will
+appear. Click on "Tactical Overview". If firefox fails to start from the button, start
+it manually and direct it to http://hades33/mon
+
+\subsection{DAQ-Operation}
+
+
+The main task of the DAQ-Operator is to watch the
+Tactical-Overview window and check that all buttons are green.
+The essential numbers (like trigger rates) have to be in limits
+given by the shift leader.
+The "Operator Guide" gives further information about each entry in
+the tactical overview. You can open it by clicking on an entry.
+It also offers a description of typical situations during data
+acquisition. It also contains instructions to solve typical
+problems. Following guides point to relevant chapters if necessary.
+
+
+
+\subsection{DAQ-Control Window}
+
+The DAQ-Control Window provides functions solutions of ocurring
+DAQ problems. The "HadesControl" Icon starts DAQ-Control.
+
+\begin{description}
+\item[DAQ-Operator] Buttons are necessary for a DAQ restart. The "DAQ-restart" guide
+describes the use of these buttons.
+
+\item[Monitor Tools] contain all observation windows.
+ \begin{description}
+ \item[CTS Mon] Opens the CTS Monitor
+ \item[Hmon] Click on "Tatical Overview" in the new Firefox window to get the mains screen.
+ If firefox fails to start from the button, start it manually
+ and direct it to \\http://hades33/mon
+ \item[Epics] Opens the Epics Monitor.
+ \item[Epics FB] Shows a status window containing Eventbuilder information.
+ \item[Daq VNC] Opens the VNC window for DAQ control used during preparation
+ \item[Chat] The DAQ users chat window
+ \end{description}
+
+\item[Eventbuilder Tools] are necessary for the control of Eventbuilders.
+ \begin{description}
+ \item[Stop EB] stops all EB.
+ \item[Restart EB] starts the EB with the last settings again
+ \item[Prefix XX] restarts the EB and sets the file prefix to a new one
+ \end{description}
+
+\item[Expert Tools]
+ \begin{description}
+ \item[CTS Scope] Opens the window oscilloscope connected to the CTS for
+ signal adjustment
+ \item[Reload RPC Thresholds] Loads the settings for trigger boards of RPC
+ in case the count rates on the CTS monitor are wrong
+ \item[Restart EB IOC] If some of the entries in the Epics Eventbuilder Monitor
+ are white, use this button to restart them
+ \item[Restart Hmon] Restarts the browser-based monitoring tools
+ \item[Start / Stop Speech Output] Temporarily stops the speech output for errors
+ \end{description}
+
+\end{description}
+
+
+
+
+
+\subsection{Eventbuilder-Stop}
+
+In the case of beam breaks etc. the shift leader decides to
+change the mode of data taking or even stop data taking (DAQ
+system is still running - in general, writing test files is better
+than stopping EB!).
+
+\begin{itemize}
+ \item Stop the data taking press the "StopEB" button in the "DAQ
+Control" window. In the tactical overview the first button in
+the row "EB" the text will change from EB-running to EB-stopped.
+Note that it is not necessary to stop before restarting or loading a new prefix.
+ \item To restart the EB with the current prefix, click on "Restart
+EB" in the DAQ-Control
+ \item To start the EB with a different prefix, click on one of the
+buttons "Prefix ...". N.B., that the "Prefix NoFile" button
+starts the event builder in dummy mode, i.e. no file is written.
+\end{itemize}
+
+
+
+\subsection{DAQ-Restart}
+
+In the case the DAQ is not working correctly, the DAQ has to be
+restarted. DAQ-Control provides the necessary operations for
+a DAQ restart.
+
+\begin{enumerate}
+ \item Press "Start DAQ" to restart DAQ. An orange window appears and
+should disappear after 30s-40s if the restart was successful.
+An unsuccessful attempt is indicated by an error message in
+the orange window. Try a second DAQ restart, if the first
+one failed.
+ \item In the case of an unsuccessful DAQ restart a MDC Power Cycle
+has to be performed. The steps of a MDC Power Cycle are described
+in the Operator Guide Chapter 34.2. After this operation the DAQ
+has to be restarted. Follow the instructions given in step "1)".
+ \item In the Case "2)" failed, the "RebootMDCHub" icon should be used.
+After pressing "RebootMDCHub" and waiting 30 seconds, the DAQ has to be
+restarted which is described in "1)".
+ \item In the case step "3)" was not successful, a "Full Power Cycle" has to be
+performed. This procedure is described in the "Operator Guide Chapter 33.1"
+Restart DAQ following the steps in "1)" .
+ \item The DAQ expert has to be called if the DAQ is still not working.
+\end{enumerate}
+
+
+All DAQ-Control Tools will open a orange window with their output which disappears
+after they finished. Make sure that no two orange windows are open at the same time.
+