]> jspc29.x-matter.uni-frankfurt.de Git - daqdocu.git/commitdiff
few words of advice
authorJan Michel <j.michel@gsi.de>
Wed, 27 Feb 2019 13:34:07 +0000 (14:34 +0100)
committerJan Michel <j.michel@gsi.de>
Fri, 30 Aug 2019 11:31:24 +0000 (13:31 +0200)
hadesoperator/main.tex

index 40270e4665404909fe3ff83d028aaab0264214cd..644a9430c8b36651076e1496a8bd162214b6f635 100644 (file)
 \clearpage
 \tableofcontents
 
+\cleardoublepage
 \part{General Advice}
-Please read the additional page with notes for the DAQ Operator.
 
-\cleardoublepage
+
+\begin{itemize*}
+\item \textbf{Please read the additional page with notes for the DAQ Operator.}
+
+\item If one board is missing, do not panic! Do not risk many seconds of possible data taking for one missing board. As a rough guide 1 MDC and/or 2 RICH boards missing is acceptable. If a board goes missing after an hour of data taking, you can restart the DAQ, but don't do it too often in case of frequent failures.
+
+\item If the high voltage on some detectors is not at nominal values, it's perfectly normal to get some warnings for this subsystem, like boards that don't deliver any data. Always check with the detector responsible to see whether this is expected behavior or an error in the DAQ.
+
+\item Don't forget to monitor the QA windows to see whether data quality is ok.
+
+
+
+\clearpage
 \part{Control}
 \input{daqcontrol}