]> jspc29.x-matter.uni-frankfurt.de Git - daqdocu.git/commitdiff
update operator manual
authorJan Michel <mail@janmichel.eu>
Wed, 9 Feb 2022 14:03:36 +0000 (15:03 +0100)
committerJan Michel <mail@janmichel.eu>
Wed, 9 Feb 2022 14:03:36 +0000 (15:03 +0100)
hadesoperator/generalremarks.tex
hadesoperator/powercycles.tex

index 04a1010a953b1cffb5f3de82a0a969fc2b5a1e1b..cf055009b209ec0381d637661084acdbe449df35 100644 (file)
@@ -1,7 +1,7 @@
 
 \part{Daily News for the Operator}
 
-\textbf{2022/02/05 - this page will be updated during the beamtime}
+\textbf{2022/02/06 - this page will be updated during the beamtime}
 \begin{itemize*}
   \item Always keep an eye on the rate plots (``Main Screen 4'' on the web page). If you notice any 
 asymmetry between sectors / parts of detectors, try to do a reload of thresholds for the detector 
@@ -10,6 +10,7 @@ talk to the detector expert, e.g. a power cycle of the frontends might be necess
 \begin{itemize*}
 \item e.g. in ECal a row of 8 green dots appear (-> ECal Padiwa Powercycle)
 \item e.g. in TOF one sector has a lower/higher rate (-> Tresholds TOF)
+\item e.g. in STS a group of 8 blue channels appear (-> Reset STS Thresholds)
 \end{itemize*}
 
   \item Every 1 to 2 hours, when you do a DAQ restart, please do a ``Start Stop Trigger'', ``Reboot 
@@ -18,8 +19,13 @@ DiRich'' and a ``Reboot ECal'' before.
   \item After any of the ``Reboot Hubs`` and DAQ restart: If Eventbuilders do not work, do 
 a ''Fix missing IP`` and another DAQ restart.
 
-  \item There is a ''Trigger`` error every now and then, from a board in RICH (70a7), which also 
-causes some ''Evt w/ errors``. This is a known, but no real issue and can be ignored.
+%   \item There is a ''Trigger`` error every now and then, from a board in RICH (70a7), which also 
+% causes some ''Evt w/ errors``. This is a known, but no real issue and can be ignored.
+
+  \item After any power cycle, pay attention to the rate display from the subsystems. Especially 
+ECal and STS likely need some manual action to get proper settings for all front-ends again (see 
+first point in this list).
+  
 
 \end{itemize*}
 \clearpage
index 6175dbd1d181cfc11de5d06e8dbef259a76b9daf..f062ef4620546936811a053cbf9d3759a47554bf 100644 (file)
@@ -52,21 +52,22 @@ A full powercycle should only be done after contact with an expert. Follow the g
 This should be performed at least once a day, when there is a break of ~ 15 minutes and in presence 
 of the DAQ expert: {\bf To be updated for 2022!}
 \begin{enumerate}
-\item Switch off beam on control panel
+\item Switch off beam on control panel\\
+      Switch EB to No File
 \item MDC power supply group off (EPICS)\\
-      Main power supply group power cycle (EPICS)  
+      Common Group power supply group power cycle (EPICS)  
 \item RICH power supply group power cycle (EPICS) 
 \item ECAL Padiwa Powercycle \\
       Hodo Powercycle\\
       Start Powercycle \\
-      STS Fee \\
+      STS Fee Powercycle\\
       iTof Powercycle \\
-      Triggerbox Beam \\
+      Triggerbox Beam Powercycle
 
 
 
 \item Reprogram FPGA \\ 
-      BLR Reload Settings
+      BLR Reinit FPGA
 \item Start DAQ (x2, because of MDC Hubs)   
 \item Run Fix Missing IP
 \item MDC power supply group on (EPICS)