</register>
<register name="MonitorStatus" address="0004" mode="r" >
<description>Status information of the monitoring block</description>
- <field name="MonitorFifoLevel" start="0" bits="10" format="unsigned" >
+ <field name="MonitorFifoLevel" start="0" bits="13" format="unsigned" >
<description>Number of data words in fifo for first input</description>
</field>
- <field name="MonitorFifoWrite" start="11" bits="1" format="boolean" >
+ <field name="MonitorFifoWrite" start="15" bits="1" format="boolean" >
<description>Write signal for fifos</description>
</field>
- <field name="MonitorWordCount" start="16" bits="12" format="unsigned" >
+ <field name="MonitorWordCount" start="16" bits="16" format="unsigned" >
<description>Word counter of Fifo control logic</description>
</field>
</register>
<field name="MonitorFifoSelect" start="16" mode="rw" bits="5" format="unsigned">
<description>Select the input signal to the Fifo, if the single-fifo version is implemented</description>
</field>
+ <field name="ExtTrigSelect" start="24" mode="rw" bits="5" format="unsigned">
+ <description>Select the input channel used as external trigger</description>
+ </field>
+ <field name="ExtTrigEnable" start="31" mode="rw" bits="5" format="boolean">
+ <description>Enable external trigger - recording starts when selected channel goes high after MonitorTrigger</description>
+ </field>
</register>
</group>