digit FPGA (0-4) \\
2000 - 2FFF & MDC OEP & 2nd digit: MDC layer (0-3); 3rd digit: sector (0-5); 4th digit MBO (0-F) \\
3000 - 31FF & RICH ADCM & 3rd digit: sector (0-5); 4th digit: segment (0-4) \\
-3200 - 37FF & Shower AddOn & 3rd digit: sector (0-5); 4th digit: FPGA (0-2) \\
3800 - 38FF & Pion & 3rd digit station, 4th digit side (x/y)\\
-4000 - 400F & Start & Start detector \\
-4010 - 401F & Veto & Veto detector \\
-4400 - 47FF & Wall & 3 TRBs for forward wall \\
-4800 - 4BFF & RPC & 3rd digit: sector (0-5), 4th digit: segment (0-3) \\
-4C00 - 4FFF & TOF & 3rd digit: sector (0-5); 4th digit: 0 for normal TRB, 1 for additional TRB to resemble broken channels\\
-5000 - 50FF & StartTRB3 & Additional TDC TRB3 for Start. 3rd digit: 0: Start, 1: Veto, F:
-Testsetups. 4th digit: FPGA number (0-3)\\
+5000 - 50FF & StartTRB3 & TRB3 for Start. 3rd digit: 0: Start, 1: Veto. 4th digit: FPGA (0-3)\\
5555 & SEB & Dummy Address used in headers generated by SubEventBuilders \\
+5800 - 58FF & RPC & 3rd digit sector (0..5), 4th digit TDC (0..8) \\
+5C00 - 5CFF & TOF & 3rd digit sector (0..6), 4th digit TDC (0..3) \\
6000 - 60FF & Ecal & Ecal read-out. 3rd digit: Sector, 4th digit: Readout Board (0-6)\\
6400 - 64FF & FT & t.b.d. \\
6800 - 68FF & f-RPC & t.b.d.\\
7000 - 7FFF & RICH & DiRich modules. 2nd/3rd digit backplane number, 4th digit: DiRich (0-11)\\
8000 - 80FF & Central Hub & central hub\\
-8100 - 81FF & MDC Hub & Hub for inner MDC (3rd digit 0) or outer MDC (3rd digit 1)\\
-8200 - 82FF & RICH Combiner & RICH Combiner boards. Last two digits: backplane number\\
-8300 - 83FF & RICH Hubs & Hubs for old RICH, 3rd digit: sector divided by 2 \\
+8100 - 81FF & MDC Hub & Hub for inner MDC (3rd digit 0) or outer MDC (1)\\
83C0 - 83DF & RICH Hubs & Hubs for old RICH, 4th digit: hub number (0..13)\\
-8400 - 84FF & RPC Hubs & Hubs for RPC, 3rd digit: sector divided by 3 \\
-8500 - 85FF & Shower Hub & \\
-8600 - 86FF & TOF Hub & \\
-8700 - 87FF & Forward Wall Hub & \\
-8800 - 88FF & Start/Veto/CTS Hub& (8880: Start-TRB3, 8890 Veto-TRB3, 88F0 Start-TRB3 for tests)\\
+84C0 - 84CF & RPC Hubs & Hubs for RPC, 3rd digit: sector (0..5) \\
+86C0 - 86FF & TOF Hub & Hubs (central FPGA TRB3), 3rd digit: sector(0..6)\\
+8800 - 88FF & Start/Veto/CTS Hub& (8880: Start-TRB3, 8890 Veto-TRB3)\\
8900 - 89FF & Pion Tracker Hub & 3rd digit: station\\
8A00 - 8AFF & Ecal Hubs& 4th digit: pseudo-sector\\
8B00 - 8BFF & FT Hubs &3rd digit: board number \\
8C00 - 8CFF & f-RPC Hubs & t.b.d.\\
F000 - FDFF & Test Setups & \\
-FE00 - FEFF & Reserved & Reserved for extension of broadcast addresses \\
-FF00 - FFFF & Broadcasts &
+FE00 - FFFF & Broadcasts & Reserved for extension of broadcast addresses
\end{tabularx}
\caption{Network Addresses}
\label{networkaddresses}
\end{center}
\end{table}
+\begin{table}[hb]
+\begin{center}
+\begin{tabularx}{\textwidth}{l|l|X}
+\textbf{Address(es)} & \textbf{Board(s)} & \textbf{Description} \\
+\textbf{Outdated} &&\\
+\hline
+3200 - 37FF & Shower AddOn & 3rd digit: sector (0-5); 4th digit: FPGA (0-2) \\
+4000 - 400F & Start & Start detector \\
+4010 - 401F & Veto & Veto detector \\
+4400 - 44FF & Wall & 3 TRBs for forward wall \\
+4800 - 4BFF & RPC & 3rd digit: sector (0-5), 4th digit: segment (0-3) \\
+4C00 - 4FFF & TOF & 3rd digit: sector (0-5); 4th digit: 0 for normal TRB, 1 for additional TRB to resemble broken channels\\
+8200 - 82FF & RICH Combiner & RICH Combiner boards. Last two digits: backplane number\\
+8300 - 83FF & RICH Hubs & Hubs for old RICH, 3rd digit: sector divided by 2 \\
+8400 - 847F & RPC Hubs & Hubs for RPC, 3rd digit: sector divided by 3 \\
+8500 - 85FF & Shower Hub & \\
+8600 - 867F & TOF Hub & \\
+8700 - 87FF & Forward Wall Hub &
+
+\end{tabularx}
+\caption{Outdated Network Addresses}
+\label{networkaddresses}
+\end{center}
+\end{table}
+
\subsection{Replacement Boards}
\label{ReplacementAddresses}
\begin{center}
\begin{tabularx}{\textwidth}{l|l|l|X}
\textbf{System} & \textbf{ID} & \textbf{Number} & \textbf{Description} \\
-CTS & 0000 - 00FF & 1(*) & only with the old CTS board!\\
MDC & 1000 - 17FF & 12 & second digit is inner(0) or outer(1) MDC, 3rd digit is the sector \\
+RICH (new) & 83C0 - 83CF & 13 & RICH hubs\\
+RPC (new) & 84C0 - 84FF & 6 & \\
+TOF (new) & 86C0 - 86FF & 7 & \\
+Start/Veto & 8800 - 887F & 1 & Start / Veto and CTS \\
+StartTRB3 & 8880 - 88FF & 2 & additional TRB3 with TDC data (8880: Start-TRB3, 8890 Veto-TRB3,
+88F0 Start-TRB3 for tests) \\
+Pion & 8900 - 89FF & 2 & Pion Tracker. 3rd digit is the station \\
+Ecal & 8A00 - 8A0F & 6 & Calorimeter.\\
+FT & 8B00 - 8BFF & 10 & Forward Tracker\\
+f-RPC & 8C00 - 8CFF & 4 & Forward RPC\\
+\hline
+\textbf{Outdated} & (2019) && \\
+\hline
+CTS & 0000 - 00FF & 1(*) & only with the old CTS board!\\
Shower & 3200 - 33FF & 6 & 3rd digit is the sector \\
Forw. Wall & 4400 - 47FF & 3(*) & last digit is the segment of FW \\
RPC & 4800 - 4BFF & 24(*) & 3rd digit is the sector, last digit normal(0) or additional(1) TRB \\
TOF & 4C00 - 4FFF & 9(*) & 3rd digit is normal(0) or additional(1) TRB, last digit is the sector \\
MDC & 8100 - 81FF & 2(*) & MDC readout via Hub \\
RICH (old) & 8300 - 837F & 3 & last digit is the sector divided by 2 \\
-RICH (new) & 83C0 - 83CF & 13 & RICH hubs\\
-RPC & 8400 - 84FF & 2 & RPC readout via GbE \\
+RPC (old) & 8400 - 84FF & 2 & RPC readout via GbE \\
+TOF (old) & 8600 - 86FF & 1 & TOF readout via GbE \\
Shower & 8500 - 85FF & 1(*) & Shower readout via Hub \\
-TOF & 8600 - 86FF & 1 & TOF readout via GbE \\
Wall & 8700 - 87FF & 1 & Forward Wall readout via GbE \\
-Start/Veto & 8800 - 887F & 1 & Start / Veto and CTS \\
-StartTRB3 & 8880 - 88FF & 2 & additional TRB3 with TDC data (8880: Start-TRB3, 8890 Veto-TRB3,
-88F0 Start-TRB3 for tests) \\
-Pion & 8900 - 89FF & 2 & Pion Tracker. 3rd digit is the station \\
-Ecal & 8A00 - 8A0F & 6 & Calorimeter.\\
-FT & 8B00 - 8BFF & & Forward Tracker\\
-f-RPC & 8C00 - 8CFF & & Forward RPC\\
+
\end{tabularx}
\caption{Reserved SubEvent IDs Ranges. Ranges marked with a (*) are not going to be used in the standard setup.}