]> jspc29.x-matter.uni-frankfurt.de Git - daqdocu.git/commitdiff
add new addresses and subeventids for TOF/RPC
authorJan Michel <j.michel@gsi.de>
Fri, 30 Aug 2019 11:29:12 +0000 (13:29 +0200)
committerJan Michel <j.michel@gsi.de>
Fri, 30 Aug 2019 11:31:24 +0000 (13:31 +0200)
networkaddresses.tex

index d6ccf638a21c3bebc1315e15a0512090a0783f99..f35aa8a9c2ffe0eed0769f57ea1c1438ef86ccab 100755 (executable)
@@ -15,43 +15,58 @@ On boards with two or more FPGAs each FPGA gets its own address. The FPGA provid
 digit FPGA (0-4) \\
 2000 - 2FFF & MDC OEP & 2nd digit: MDC layer (0-3); 3rd digit: sector (0-5); 4th digit MBO (0-F) \\
 3000 - 31FF & RICH ADCM & 3rd digit: sector (0-5); 4th digit: segment (0-4) \\
-3200 - 37FF & Shower AddOn & 3rd digit: sector (0-5); 4th digit: FPGA (0-2) \\
 3800 - 38FF & Pion  & 3rd digit station, 4th digit side (x/y)\\
-4000 - 400F & Start & Start detector \\
-4010 - 401F & Veto & Veto detector \\
-4400 - 47FF & Wall & 3 TRBs for forward wall \\
-4800 - 4BFF & RPC & 3rd digit: sector (0-5), 4th digit: segment (0-3) \\
-4C00 - 4FFF & TOF & 3rd digit: sector (0-5); 4th digit: 0 for normal TRB, 1 for additional TRB to resemble broken channels\\
-5000 - 50FF & StartTRB3 & Additional TDC TRB3 for Start. 3rd digit: 0: Start, 1: Veto, F: 
-Testsetups. 4th digit: FPGA number (0-3)\\ 
+5000 - 50FF & StartTRB3 & TRB3 for Start. 3rd digit: 0: Start, 1: Veto. 4th digit: FPGA (0-3)\\ 
 5555        & SEB & Dummy Address used in headers generated by SubEventBuilders \\
+5800 - 58FF & RPC & 3rd digit sector (0..5), 4th digit TDC (0..8) \\
+5C00 - 5CFF & TOF & 3rd digit sector (0..6), 4th digit TDC (0..3) \\ 
 6000 - 60FF & Ecal & Ecal read-out. 3rd digit: Sector, 4th digit: Readout Board (0-6)\\
 6400 - 64FF & FT & t.b.d. \\
 6800 - 68FF & f-RPC & t.b.d.\\
 7000 - 7FFF & RICH & DiRich modules. 2nd/3rd digit backplane number, 4th digit: DiRich (0-11)\\
 8000 - 80FF & Central Hub & central hub\\
-8100 - 81FF & MDC Hub & Hub for inner MDC (3rd digit 0) or outer MDC (3rd digit 1)\\
-8200 - 82FF & RICH Combiner & RICH Combiner boards. Last two digits: backplane number\\
-8300 - 83FF & RICH Hubs & Hubs for old RICH, 3rd digit: sector divided by 2 \\
+8100 - 81FF & MDC Hub & Hub for inner MDC (3rd digit 0) or outer MDC (1)\\
 83C0 - 83DF & RICH Hubs & Hubs for old RICH, 4th digit: hub number (0..13)\\
-8400 - 84FF & RPC Hubs & Hubs for RPC, 3rd digit: sector divided by 3 \\
-8500 - 85FF & Shower Hub & \\
-8600 - 86FF & TOF Hub & \\
-8700 - 87FF & Forward Wall Hub & \\
-8800 - 88FF & Start/Veto/CTS Hub& (8880: Start-TRB3, 8890 Veto-TRB3, 88F0 Start-TRB3 for tests)\\
+84C0 - 84CF & RPC Hubs & Hubs for RPC, 3rd digit: sector (0..5) \\
+86C0 - 86FF & TOF Hub & Hubs (central FPGA TRB3), 3rd digit: sector(0..6)\\
+8800 - 88FF & Start/Veto/CTS Hub& (8880: Start-TRB3, 8890 Veto-TRB3)\\
 8900 - 89FF & Pion Tracker Hub & 3rd digit: station\\
 8A00 - 8AFF & Ecal Hubs& 4th digit: pseudo-sector\\
 8B00 - 8BFF & FT Hubs &3rd digit: board number \\
 8C00 - 8CFF & f-RPC Hubs & t.b.d.\\
 F000 - FDFF & Test Setups & \\
-FE00 - FEFF & Reserved & Reserved for extension of broadcast addresses \\
-FF00 - FFFF & Broadcasts &
+FE00 - FFFF & Broadcasts & Reserved for extension of broadcast addresses
 \end{tabularx}
 \caption{Network Addresses}
 \label{networkaddresses}
 \end{center}
 \end{table}
 
+\begin{table}[hb]
+\begin{center}
+\begin{tabularx}{\textwidth}{l|l|X}
+\textbf{Address(es)} & \textbf{Board(s)} & \textbf{Description} \\
+\textbf{Outdated} &&\\
+\hline
+3200 - 37FF & Shower AddOn & 3rd digit: sector (0-5); 4th digit: FPGA (0-2) \\
+4000 - 400F & Start & Start detector \\
+4010 - 401F & Veto & Veto detector \\
+4400 - 44FF & Wall & 3 TRBs for forward wall \\
+4800 - 4BFF & RPC & 3rd digit: sector (0-5), 4th digit: segment (0-3) \\
+4C00 - 4FFF & TOF & 3rd digit: sector (0-5); 4th digit: 0 for normal TRB, 1 for additional TRB to resemble broken channels\\
+8200 - 82FF & RICH Combiner & RICH Combiner boards. Last two digits: backplane number\\
+8300 - 83FF & RICH Hubs & Hubs for old RICH, 3rd digit: sector divided by 2 \\
+8400 - 847F & RPC Hubs & Hubs for RPC, 3rd digit: sector divided by 3 \\
+8500 - 85FF & Shower Hub & \\
+8600 - 867F & TOF Hub & \\
+8700 - 87FF & Forward Wall Hub &
+
+\end{tabularx}
+\caption{Outdated Network Addresses}
+\label{networkaddresses}
+\end{center}
+\end{table}
+
 
 \subsection{Replacement Boards}
 \label{ReplacementAddresses}
@@ -93,26 +108,32 @@ In summary, the only boards that send subevents are the Hubs, MDC Concentrators
 \begin{center}
 \begin{tabularx}{\textwidth}{l|l|l|X}
 \textbf{System} & \textbf{ID} & \textbf{Number} & \textbf{Description} \\
-CTS        & 0000 - 00FF & 1(*)  & only with the old CTS board!\\
 MDC        & 1000 - 17FF & 12 & second digit is inner(0) or outer(1) MDC, 3rd digit is the sector \\
+RICH (new) & 83C0 - 83CF & 13  &  RICH hubs\\
+RPC (new)  & 84C0 - 84FF & 6  & \\
+TOF (new)  & 86C0 - 86FF & 7 & \\
+Start/Veto & 8800 - 887F & 1 & Start / Veto and CTS \\
+StartTRB3  & 8880 - 88FF & 2 & additional TRB3 with TDC data (8880: Start-TRB3, 8890 Veto-TRB3, 
+88F0 Start-TRB3 for tests) \\
+Pion       & 8900 - 89FF & 2 & Pion Tracker. 3rd digit is the station \\
+Ecal       & 8A00 - 8A0F & 6 & Calorimeter.\\
+FT         & 8B00 - 8BFF & 10 & Forward Tracker\\
+f-RPC      & 8C00 - 8CFF & 4 & Forward RPC\\
+\hline
+\textbf{Outdated} & (2019) && \\
+\hline
+CTS        & 0000 - 00FF & 1(*)  & only with the old CTS board!\\
 Shower     & 3200 - 33FF & 6  & 3rd digit is the sector \\
 Forw. Wall & 4400 - 47FF & 3(*)  & last digit is the segment of FW \\
 RPC        & 4800 - 4BFF & 24(*) & 3rd digit is the sector, last digit normal(0) or additional(1) TRB \\
 TOF        & 4C00 - 4FFF & 9(*)  & 3rd digit is normal(0) or additional(1) TRB, last digit is the sector \\
 MDC        & 8100 - 81FF & 2(*)  & MDC readout via Hub \\
 RICH (old) & 8300 - 837F & 3  & last digit is the sector divided by 2 \\
-RICH (new) & 83C0 - 83CF & 13  &  RICH hubs\\
-RPC        & 8400 - 84FF & 2  & RPC readout via GbE \\
+RPC (old)  & 8400 - 84FF & 2  & RPC readout via GbE \\
+TOF (old)  & 8600 - 86FF & 1  & TOF readout via GbE \\
 Shower     & 8500 - 85FF & 1(*) & Shower readout via Hub \\
-TOF        & 8600 - 86FF & 1  & TOF readout via GbE \\
 Wall       & 8700 - 87FF & 1  & Forward Wall readout via GbE \\
-Start/Veto & 8800 - 887F & 1 & Start / Veto and CTS \\
-StartTRB3  & 8880 - 88FF & 2 & additional TRB3 with TDC data (8880: Start-TRB3, 8890 Veto-TRB3, 
-88F0 Start-TRB3 for tests) \\
-Pion       & 8900 - 89FF & 2 & Pion Tracker. 3rd digit is the station \\
-Ecal       & 8A00 - 8A0F & 6 & Calorimeter.\\
-FT         & 8B00 - 8BFF & & Forward Tracker\\
-f-RPC      & 8C00 - 8CFF & & Forward RPC\\
+
 \end{tabularx}
 \caption{Reserved SubEvent IDs Ranges. Ranges marked with a (*) are not going to be used in the standard setup.}
 \label{subeventidtable}