hadesoperator/generalremarks.tex
hadesoperator/powercycles.tex

index 1399f7c9c7b3c022845ef632567951f1cb37a7cf..04a1010a953b1cffb5f3de82a0a969fc2b5a1e1b 100644 (file)
@@ -1,12 +1,16 @@
 
 \part{Daily News for the Operator}
 
-\textbf{2022/02/04 - this page will be updated during the beamtime}
+\textbf{2022/02/05 - this page will be updated during the beamtime}
 \begin{itemize*}
   \item Always keep an eye on the rate plots (``Main Screen 4'' on the web page). If you notice any 
 asymmetry between sectors / parts of detectors, try to do a reload of thresholds for the detector 
 (do a ``Start Stop DAQ'' before and after to avoid taking corrupted data). If this doesn't help, 
 talk to the detector expert, e.g. a power cycle of the frontends might be necessary.
+\begin{itemize*}
+\item e.g. in ECal a row of 8 green dots appear (-> ECal Padiwa Powercycle)
+\item e.g. in TOF one sector has a lower/higher rate (-> Tresholds TOF)
+\end{itemize*}
 
   \item Every 1 to 2 hours, when you do a DAQ restart, please do a ``Start Stop Trigger'', ``Reboot 
 DiRich'' and a ``Reboot ECal'' before.
index fe2c1b8eaf462096e816ee3170cc3039cde9646b..6175dbd1d181cfc11de5d06e8dbef259a76b9daf 100644 (file)
@@ -53,7 +53,9 @@ This should be performed at least once a day, when there is a break of ~ 15 minu
 of the DAQ expert: {\bf To be updated for 2022!}
 \begin{enumerate}
 \item Switch off beam on control panel
-\item MDC power supply group off (EPICS) 
+\item MDC power supply group off (EPICS)\\
+      Main power supply group power cycle (EPICS)  
+\item RICH power supply group power cycle (EPICS) 
 \item ECAL Padiwa Powercycle \\
       Hodo Powercycle\\
       Start Powercycle \\
@@ -61,17 +63,18 @@ of the DAQ expert: {\bf To be updated for 2022!}
       iTof Powercycle \\
       Triggerbox Beam \\
 
-\item RICH power supply group power cycle (EPICS) \\
-      Main power supply group power cycle (EPICS) 
+
 
 \item Reprogram FPGA \\ 
       BLR Reload Settings
-\item Start DAQ (x2, because of MDC Hubs)      
+\item Start DAQ (x2, because of MDC Hubs)   
+\item Run Fix Missing IP
 \item MDC power supply group on (EPICS)
       MDC LV Turn On All Relais
 \item Reboot OEP
 \item Start DAQ
-\item Load ECal Thresholds
-\item Check Eventbuilders getting data / all boards have IPs
+\item Thresholds STS Reset\
+      Check Eventbuilders getting data / all boards have IPs
+
 \item Switch on beam
 \end{enumerate}