]> jspc29.x-matter.uni-frankfurt.de Git - daqtools.git/commitdiff
adding new register to enable multiplicity based trigger
authorJan Michel <j.michel@gsi.de>
Fri, 18 Mar 2016 17:33:09 +0000 (18:33 +0100)
committerJan Michel <j.michel@gsi.de>
Fri, 18 Mar 2016 17:33:09 +0000 (18:33 +0100)
xml-db/database/InputMonitorTrb3sc.xml

index 31b72725eb2d29598fbd4b7b9091e72e2008c761..0b5d674b4b446679b5bc508a2f17fccd86c989e8 100644 (file)
          <description>Number of outputs of the trigger logic</description>
       </field>
     </register>
-    
+    <register name="Multiplicity" address="0032" mode="r" >
+      <description>Multiplicity based on enabled inputs to output 1. Output used is 2! Coincidence interval is fixed to 4 clock cycles</description>
+      <field  name="MultLimit" start="16" bits="8" format="unsigned" noflag="true" mode="rw">
+         <description>Number of inputs firing at the same time required to cause a trigger</description>
+      </field>
+      <field  name="MultActual" start="0" bits="8" format="unsigned" noflag="true">
+         <description>Current number of active inputs.</description>
+      </field>
+    </register>    
         