\item[Bit 6] Force update Shower pedestals trigger (write ..1..0)
\item[Bit 7] Disable Shower pedestals update (generated once during each spill off)
\item[Bit 8] Enable Shower calibration trigger
+ \item[Bit 14] Enable beam inhibit
+ \item[Bit 31] Enable trigger line test, this works together with self trigger (set the requried frequency)
\end{description}
\item [0xA0C1] LVL1/LVL2 trigger settings:
\begin{description}
\begin{description}
\item[Bit 23 -- 0] Number of events per EB
\end{description}
- \item [0xA0E3] LVL2 - events per EB
+ \item [0xA0E3] Self trigger
\begin{description}
\item[Bit 27 -- 0] When 0 the internal triggering is disabled, when different than 0 the internal trigger is enabled and $frequency = 1/Value*10ns $
\end{description}
+ \item [0xA0E4] LVL1 trigger information
+ \begin{description}
+ \item[Bit 6 -- 0] LVL1 trigger information(6 -- 0)
+ \item[Bit 13 -- 8] LVL1 trigger information(13 -- 8)
+ \end{description}
+
\end{description}
%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%