]> jspc29.x-matter.uni-frankfurt.de Git - mvd_docu.git/commitdiff
added power measurement results
authorMichael Wiebusch <stratomaster@gmx.net>
Tue, 30 Jul 2013 12:28:35 +0000 (14:28 +0200)
committerMichael Wiebusch <stratomaster@gmx.net>
Tue, 30 Jul 2013 12:28:35 +0000 (14:28 +0200)
electronics/powermeasurements.tex

index 1984ed55e35cc1f50ab2c4fa9e431a4e8f737ce8..de0129ebbf7762b44b26adb2c82d38c56faa1c1c 100644 (file)
 \maketitle
 
 \section{Measured power consumption}
-
+\begin{itemize}
+\item Current through VDD: 65-100 \rm{mA}, strongly depending on threshold settings.
+\item Current through VDDA: (168\pm1) \rm{mA}, weakly depending on threshold settings. (Might be an effect caused by voltage drop
+along the GND lines of the FPC. After all GND and GNDA ?are? connected to each other in the sensor)
+\end{itemize}
 \section{Noise measurement and Requirements}
 
 \end{document}