From: Jan Michel Date: Thu, 10 Mar 2022 19:37:43 +0000 (+0100) Subject: update operator notes X-Git-Url: https://jspc29.x-matter.uni-frankfurt.de/git/?a=commitdiff_plain;h=583009ec54e332c770df71432d8535d4d8ae9ddf;p=daqdocu.git update operator notes --- diff --git a/hadesoperator/powercycles.tex b/hadesoperator/powercycles.tex index 2752666..bec001a 100644 --- a/hadesoperator/powercycles.tex +++ b/hadesoperator/powercycles.tex @@ -36,6 +36,10 @@ The 3.3V supply might be blocked by the temperature interlock - restart DAQ, the \subsection*{Other Subdetectors} Check section \ref{powersupplies} to see which power supply to switch. +\subsection*{Full Powercycle} +A full powercycle should only be done after contact with an expert. Follow the guide for the +``Daily DAQ reboot''. + \subsection{Jörg's helpful tips} \subsubsection*{ECAL / RPC} @@ -71,12 +75,11 @@ TOF" is needed. iTOF" is needed. If this doesn't help, do a "Powercycle iTOF Padiwa" and try again. \end{itemize} -\subsubsection*{Procedure if TRBnet fails} -If suddenly TRBnet fails (normally indicated by every button on the tactical display blinking red) -do a powercycle of the common group. Thereafter you need to switch on the RICH LV again after -waiting about 10 seconds. -If you powercycled the common group, check all the thresholds and rates as explained in the ECAL, -RPC and TOF sections. +\subsubsection*{"Everything failed" / 'Invaild' during startup} +If suddenly TRBnet fails (normally indicated by every button on the tactical display blinking red), +you usually can solve the problem by using the Reboot buttons. Start with RICH, ECAL, RPC and then the +rest. Try to restart after a couple of reboots before continuing. +Rarely a powercycle of RICH or the Common Group is needed. \subsubsection*{General remark} \begin{itemize} @@ -93,25 +96,27 @@ server room. \end{itemize} -\subsection*{Full Powercycle} -A full powercycle should only be done after contact with an expert. Follow the guide for the -``Daily DAQ reboot''. \section{Full Power Cycle / Daily DAQ reboot} -This should be performed at least once a day, when there is a break of ~ 15 minutes and in presence -of the DAQ expert: {\bf To be updated for 2022!} +This should be performed at least once a day, when there is a break of ~ 15 minutes. Steps listed under the same item can be done in parallel. \begin{enumerate} \item Switch off beam on control panel\\ Switch EB to No File \item MDC power supply group off (EPICS)\\ - Common Group power supply power cycle (EPICS) -\item RICH power supply group power cycle (EPICS) + Common Group power supply power off (EPICS) +\item Common Group power supply power on (EPICS) +\item (wait 10 seconds) +\item RICH power supply group power on (EPICS) + \begin{itemize*} + \item Check that all supplies are on. Sometimes the 3.3V supply doesn't switch on due to an interlock. + \end{itemize*} \item Start DAQ (it won't run, that's fine) \begin{itemize*} \item Check if all RPC and ECAL boards are there. If not, redo ECAL/RPC powercycle in EPICS and repeat \item Check if all iTOF boards are there. If not, redo MDC/TOF powercycle in EPICS and repeat + \item Check if all Start boards are there. If not, redo Powercycle Start and repeat \end{itemize*} \item Reprogram FPGA \\ @@ -130,8 +135,14 @@ repeat MDC LV Turn On All Relais \item Reboot OEP \item Start DAQ -\item Thresholds STS Reset\\ - Check Eventbuilders getting data + \begin{itemize*} + \item In case of corresponding message, redo Reboot OEP as necessary and try again. + \end{itemize*} +\item Thresholds STS Reset \\ + Check Eventbuilders getting data \\ + Check all FEE to deliver proper signals. Load thresholds or do another Fee/Padiwa powercycle\\ + Check if there are no 'MBO without data' - otherwise do a powercycle for this chamber, Reboot OEP, Start DAQ + \item Switch on beam \end{enumerate}