From: Michael Wiebusch Date: Tue, 30 Jul 2013 13:41:59 +0000 (+0200) Subject: correted a detail in powermeasurements.tex X-Git-Url: https://jspc29.x-matter.uni-frankfurt.de/git/?a=commitdiff_plain;h=84a1641aaddae5284bc2c5031723b2e9dc7a4262;p=mvd_docu.git correted a detail in powermeasurements.tex --- diff --git a/electronics/powermeasurements.tex b/electronics/powermeasurements.tex index 5480998..c919558 100644 --- a/electronics/powermeasurements.tex +++ b/electronics/powermeasurements.tex @@ -12,7 +12,7 @@ \section{Measured power consumption} \begin{itemize} \item Current through VDD: 65-100 \rm{mA}, strongly depending on threshold settings. -\item Current through VDDA: (168$\pm$1) \rm{mA}, weakly depending on threshold settings. This might be an effect caused by voltage drop +\item Current through VDDA: (166$\pm$3) \rm{mA}, weakly depending on threshold settings. This might be an effect caused by voltage drop along the GND lines of the FPC. After all GND and GNDA ?are? connected to each other in the sensor. \end{itemize} \section{Noise measurement and Requirements}