From 6cbe7aff621e5013c1af203e87e9b85f5e348dda Mon Sep 17 00:00:00 2001 From: Jan Michel Date: Thu, 10 Feb 2022 20:46:45 +0100 Subject: [PATCH] update operator manual --- hadesoperator/powercycles.tex | 72 +++++++++++++++++++++++++++++------ 1 file changed, 61 insertions(+), 11 deletions(-) diff --git a/hadesoperator/powercycles.tex b/hadesoperator/powercycles.tex index f062ef4..df67335 100644 --- a/hadesoperator/powercycles.tex +++ b/hadesoperator/powercycles.tex @@ -32,17 +32,67 @@ are active again (see the list in ``EPICS Power'' -> ``RICH LV''), do a DAQ rest In the case that the power cycle triggered the temperature interlock for RICH power supplies. The 3.3V supply might be blocked by the temperature interlock - restart DAQ, then try to reset it. -\subsection*{CTS} -If a power cycle of the CTS was done, don't forget to ``Reprogram FPGA'' and -``BLR Reinit FPGA'' before the DAQ restart. - -\subsection*{STS FEE} -After a powercycle of the STS (Fee or Trb, thresholds need to be loaded manually, using ``Threshold -STS''. \subsection*{Other Subdetectors} Check section \ref{powersupplies} to see which power supply to switch. + +\subsection{Jörg's helpful tips} +\subsubsection*{ECAL / RPC} +\begin{itemize} +\item After an ECAL powercycle most often a ECAL Padiwa powercycle is needed. You can check this +looking at the ECAL rate plot seeing weird structures (e.g. 8 green dots in a row) or completely +missing parts. + +\item After the powercycle and DAQ restart often the RPC is still not fully operational. Often you +need to repeat the powercycle until RPC and ECAL (connected to same LV) are both operational again. + +\item After the first DAQ restart you should press the Fix missing IP preemptively as otherwise the +EB might fail. +\end{itemize} + +\subsubsection*{STS} +\begin{itemize} +\item Whenever you do an STS powercycle, you need to do "Thresholds STS" if it did not work (you +see e.g. blue spots in the STS Hit rate plot) do a "Thresholds STS reset" (this takes a bit longer +as it is comprised of four different scripts) +\end{itemize} + +\subsubsection*{TOF} +\begin{itemize} +\item After the TOF powercycle check if the rates in all sectors are equal - if not a "Thresholds +TOF" is needed. +\item If settings thresholds doesn't work in the first try, repeat it a couple more times. +\end{itemize} + +\subsubsection*{iTOF} +\begin{itemize} +\item After the iTOF powercycle check if the rates in all sectors are equal - if not a "Thresholds +iTOF" is needed. If this doesn't help, do a "Powercycle iTOF Padiwa" and try again. +\end{itemize} + +\subsubsection*{Procedure if TRBnet fails} +If suddenly TRBnet fails (normally indicated by every button on the tactical display blinking red) +do a powercycle of the common group. Thereafter you need to switch on the RICH LV again after +waiting about 10 seconds. +If you powercycled the common group, check all the thresholds and rates as explained in the ECAL, +RPC and TOF sections. + +\subsubsection*{General remark} +\begin{itemize} +\item If the EBs do not come up after a (or several) power cycles, try a "Fix missing IP". +\item Sometimes some MDC boards are missing for a longer time such that the tactical overview +informs you to take action. +Very often a DAQ restart is sufficient to get these boards working again. +If however after some minutes the exact same MDC boards go missing again, you should consider a LV +power cycle of the respective sectors when you restart the DAQ next time. + +\item If boards frequently fail to reboot after a power cycle you might consider switching off the +beam for the power cycling and subsequent startup procedure. You can do that via the PC in the +server room. + +\end{itemize} + \subsection*{Full Powercycle} A full powercycle should only be done after contact with an expert. Follow the guide for the ``Daily DAQ reboot''. @@ -55,13 +105,13 @@ of the DAQ expert: {\bf To be updated for 2022!} \item Switch off beam on control panel\\ Switch EB to No File \item MDC power supply group off (EPICS)\\ - Common Group power supply group power cycle (EPICS) + Common Group power supply power cycle (EPICS) \item RICH power supply group power cycle (EPICS) \item ECAL Padiwa Powercycle \\ Hodo Powercycle\\ Start Powercycle \\ STS Fee Powercycle\\ - iTof Powercycle \\ + iTof Padiwa Powercycle \\ Triggerbox Beam Powercycle @@ -70,11 +120,11 @@ of the DAQ expert: {\bf To be updated for 2022!} BLR Reinit FPGA \item Start DAQ (x2, because of MDC Hubs) \item Run Fix Missing IP -\item MDC power supply group on (EPICS) +\item MDC power supply group on (EPICS) \\ MDC LV Turn On All Relais \item Reboot OEP \item Start DAQ -\item Thresholds STS Reset\ +\item Thresholds STS Reset\\ Check Eventbuilders getting data / all boards have IPs \item Switch on beam -- 2.43.0