From ef3baff8a5f83913b55d8aee776f8e993fb422d1 Mon Sep 17 00:00:00 2001 From: hadaq Date: Fri, 2 Jul 2010 13:33:14 +0000 Subject: [PATCH] *** empty log message *** --- rich.tex | 62 ++++++++++++++++++++++++++++++++++++++++++++++++++++++++ 1 file changed, 62 insertions(+) diff --git a/rich.tex b/rich.tex index 15d1143..72b68cb 100755 --- a/rich.tex +++ b/rich.tex @@ -427,3 +427,65 @@ for operating this unit. and BIT\_HIGH settings} \label{fig:richadcsnoop} \end{figure} + +%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% +\subsection{Trigger connection} +%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%% + +The RICH ADCMv3 needs at least one cable connection to CTS. Adding a second +cable is not required, but recommended. + +\noindent A simple standard RJ45 ethernet cable is used as trigger distribution +for the RICH. The selected pinout can be found in +table~\ref{richtriggerpinout}. The name given there for the signals corresponds +to the small debug connector on the trigger distribution boards. Pins are +labeled there, the output levels are LVTTL standard. + +\noindent \textbf{Note:} It is recommended to check the correct polarity of +signals by measuring the signal levels on the RICH trigger distribution +board. The timing trigger signal must be low ($0\>\mbox{V}$) if not active, +with a positive pulse of minimum $100\>\mbox{ns}$ length if a trigger is sent. + +\noindent \textbf{Hint:} If RICH does not send data, while readout is running +perfectly, you can easily check for missing or broken timing trigger cables +by reading the channel 0 (LVL1) error bits in one of the RICH hubs (details +can be found in section~\ref{hubstatusregs}). + +\noindent One trigger distribution board is used per sector, in addition one +distribution board does the fanout for all six sectors. This main distribution +board is mounted on sector~0 top. + +\begin{table} +\begin{center} +\begin{tabularx}{\textwidth}{|c|X|X|X|X|} +\hline +\textbf{Pin} & \textbf{Name} & \textbf{Colour} & CTS pin & +\textbf{description}\\ +\hline +\hline +1 & IN2- & white/orange & ADO\_LV(61) & clock (-) \\ +2 & IN2+ & orange & ADO\_LV(60) & clock (+) \\ +3 & IN3- & white/green & --- & reserved \\ +4 & IN1- & blue & ADO\_LV(55) & timing trigger (-) \\ +5 & IN1+ & white/blue & ADO\_LV(54) & timing trigger (+) \\ +6 & IN3+ & green & --- & reserved \\ +7 & IN0- & white/brown & --- & reserved \\ +8 & IN0+ & brown & --- & reserved \\ +\hline +\end{tabularx} +\caption{RICH trigger pinout, colour codes according to T568B straight forward +cable} +\label{richtriggerpinout} +\end{center} +\end{table} + +\noindent For connection to CTS (version 1) at least two adaptor cables are +floating around, so you need to check which one you have. + +\noindent The necessary connections to the CTS adaptor cable are also marked +in table~\ref{richtriggerpinout}. + +\noindent For your orientation: usually the clock signal is on one end of the +68pin flat ribbon cable, while the timing trigger is on the fifth cable pair. + + -- 2.43.0